Insulation R-Value Calculator
Convert US R, SI RSI or an entered U-value, sum layers, or compare frame and cavity heat-flow paths. U-values are reported with their unit system explicitly identified.
By Alish Gautam, Software Developer · Updated · Calculation methodology
Start with the editable example below. Dimensions retain their physical size when units change. Region sets currency labels without converting currencies; confirm entered quotes after changing region. Thermal inputs labeled US R retain that unit in every region.
Project takeoff
Whole packages round up. Allowance is separate from purchased surplus. Prices omit labor, delivery, tax and other items unless explicitly entered.
- US R-value
- 14.5 ft²·°F·h/Btu
- SI RSI
- 2.554 m²·K/W
- SI U-value
- 0.392 W/(m²·K)
- US U-factor
- 0.069 Btu/(h·ft²·°F)
Enter complete path resistances including any intended films. The simple parallel model does not certify a complex wall, two-dimensional bridge or condensation behavior.
How it works
RSI = US R × 0.1761101838. Series resistance adds; U = 1 / resistance in matching units. Entered SI U gives RSI = 1 / U; entered US U gives R = 1 / U. Parallel U = frame fraction / frame-path R + cavity fraction / cavity-path R.
Assumptions and limitations
Enter complete path resistances including any intended films. The simple parallel model does not certify a complex wall, two-dimensional bridge or condensation behavior.
Whole packages round upward after the chosen allowance. Physical geometry and purchase reserve are separate. Manufacturer and project specifications override editable examples; the selected region does not establish a local code requirement.
Sources and boundaries
Natural Resources Canada: Keeping the Heat In — Section 3: Materials
Open the source · Web guidance; edition not stated · Reference checked 2026-10-04
Scope: Material and thermal-control guidance
Used for: R versus RSI terminology; Assembly-specific material considerations.
Does not establish: All products share one R per inch; Provincial code lookup.
Thermal conversion is a unit conversion; product resistance is an input.
ENERGY STAR: Recommended Home Insulation R-Values
Open the source · Web guidance; edition not stated · Reference checked 2026-10-04
Scope: US residential retrofit recommendations
Used for: Displayed climate-zone attic reference table.
Does not establish: Local adopted-code compliance; Manufacturer bag coverage.
The page states its guidance is based on 2021 IECC Table R402.1.3; preserve separate bare-attic and existing-insulation columns.
Australian Building Codes Board: NCC — Building Fabric
Open the source · NCC 2022 Housing Provisions, Part 13.2 · Reference checked 2026-10-04
Scope: Published housing building-fabric provisions
Used for: Assembly and climate-zone context.
Does not establish: Universal ceiling R value; Current state adoption determination.
Linked adopted 2022 text is an identified reference, not a claim that every project uses that edition. Confirm current jurisdiction adoption and project pathway.