Common Rafter Trigonometry & Formulas
In roof framing, a common rafter extends perpendicularly from the exterior wall top plate up to the central ridge board. Calculating its cut length requires three core right-triangle formulas:
Line Run = (Total Span ÷ 2) − (Ridge Board Thickness ÷ 2)For a 24 ft span with a 1.5" (0.125 ft) ridge board: Half-span is 12.0 ft, minus 0.0625 ft ridge half-thickness = 11.9375 ft effective run.
Line Length = Line Run × √(1 + (Rise ÷ 12)²)At a 6/12 pitch (multiplier 1.118034), an 11.9375 ft run yields an exact line length of 13.3465 ft (13' 4-3/16").
Understanding Birdsmouth Cuts & Saw Angles
A common rafter requires three distinct cuts:
- Ridge Plumb Cut: A vertical cut at the apex that butts flush against the ridge board. The plumb angle from the rafter top edge equals
90° − Pitch Angle. - Birdsmouth Heel (Plumb) Cut: A vertical notch cut that aligns with the exterior face of the wall stud sheathing.
- Birdsmouth Seat (Horizontal) Cut: A level horizontal notch cut that rests flat on the top wall plate (typically 3.5 inches for 2x4 framing or 5.5 inches for 2x6 framing). Per IRC Section R802.5.2, the bearing notch depth must never exceed one-third of the rafter depth.
- Eave Overhang Tail Cut: Plumb or square cut at the bottom end of the rafter tail to receive the sub-fascia board.